Athena Controls

Athena to Tempco

C10 Series(2 outputs)/TEC-2500 series(3 outputs, Universal input #1, CT/EI/VI input #2, EI input #3)

(If 5V logic SSR output is NOT needed, use TEC-220)
2500’s available with retransmission outputs(RS485, RS232, 4-20mA, 1-5Vdc, 0-10 Vdc)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
C103000-0300 TEC02001 TEC-2500-4110101 2A relay output #1, 5Vdc Logic alarm output
C103300-0300 TEC-2500-4160101 1A Triac SSR output #1,  5Vdc Logic alarm output
C105000-0300 TEC-2500-5110101 2A relay output #1, 5Vdc Logic alarm output, 11-26 Vac/Vdc
C105300-0300 TEC-2500-5160101 1A Triac SSR output #1,  5Vdc Logic alarm output, 11-26 Vac/Vdc
(Use TEC-8100 model if logic control/ CT inputs are NOT needed

X400 Series(3 outputs, 1 alarm)(3 Inputs) / TEC-8300(2 outputs, 2 alarms)(3 Inputs, Universal input #1, CT/EI/VI input #2, EI input # 3)

8300’s available with retransmission outputs(RS485, RS232, 4-20mA, 1-5Vdc, 0-10 Vdc)
Universal input for TC’s (type J, K, E, B, R, S, N, and L)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
X4003100-0300 TEC33003 TEC-8300-4111100 2A relay outputs #1 & #2, 2A alarm #1 relay
X4003500-0300 TEC33018 TEC-8300-4161100 1A Triac for SSR output #1, 2A relay output #2, 2A alarm #1 relay
X4005100-0300 TEC-8300-5111100 2A relay outputs #1 & #2, 2A alarm #1 relay, 11-26 Vac/Vdc
X4005500-0300 TEC-8300-5161100 1A Triac for SSR output #1, 2A relay output #2, 2A alarm #1 relay, 11-26 Vac/Vdc

M10 Series(2 outputs)/TEC-920 (2 outputs)

920’s available with retransmission output RS-485 data interface
Universal input for TC’s (type J, K, E, B, R, S, N, and L)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
M103000-0300 TEC15002 TEC-920-4511 2A relay for outputs #1 & #2
M103300-0300 TEC15013 TEC-920-5511 2A relay for outputs #1 & #2, 11-26 Vac/Vdc
M105000-0300 TEC15028 TEC-920-4561 1A Triac for SSR output #1, 2A relay output #2
M105300-0300 TEC15040 TEC-920-5561 1A Triac for SSR output #1, 2A relay output #2, 11-26 Vac/Vdc

M400 Series(3 outputs)/TEC-9100(2 outputs, 1 alarm)

9100’s available with retransmission/communication outputs RS485. RS232, 4-20mA, 1-5Vdc, and 0-10 Vdc
Universal input for TC’s (type J, K, E, B, R, S, N, and L)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
M4003100-0300 TEC14001 TEC-9100-4511100 2A relays outputs #1 & #2, 2A alarm relay
M4003200-0300 TEC14093 TEC-9100-4561100 1A Triac for SSR output 1, 2 A alarm relay
M4003500-0300 TEC14062 TEC-9100-4566100 1A Triac for SSR outputs #1 & #2, 2A relay output 2
M4005100-0300 TEC14059 TEC-9100-5511100 2A relay outputs #1 & #2, 2A alarm relay, 11-26 Vac/Vdc
M4005200-0300 TEC-9100-5561100 1A Triac for SSR output #1, 2 A relay output #2, 2A alarm relay, 11-26 Vac/Vdc
M4005500-0300 TEC-9100-5566100 1A Triac for SSR outputs #1 & #2, 2 A alarm relay, 11-26 Vac/Vdc

Legacy Series – Series 16 (2 outputs, 2 alarms)/TEC-9100(2 outputs, 1 alarm)

9100’s available with retransmission/communication outputs RS485. RS232, 4-20mA, 1-5Vdc, and 0-10 Vdc
All 9100’s available with NEMA 4/X ratings
All 9100’s available in Low Voltage (11-26Vac/Vdc)
Universal input for TC’s (type J, K, E, B, R, S, N, and L)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
Model16 JF-B-0-00 TEC14002 TEC-9100-4510000 2A relay output# 1
Model16 JF-B-B-00 TEC14001 TEC-9100-4511000 2A relay outputs #1 & #2
Model16 JF-F-0-00 TEC14004 TEC-9100-4530000 4-20mA output #1
Model16 JF-F-B-00 TEC14102 TEC-9100-4531000 4-20mA output #1, 2 A relay output #2
Model16 JF-S-0-00 TEC14017 TEC-9100-4520000 5VDC pulse SSRD output#1
Model16 JF-S-B-00 TEC14016 TEC-9100-4521000 5VDC pulse SSRD output#1, 2A relay output #2
Model16 JF-T-0-00 TEC14021 TEC-9100-4560000 1A Triac for SSR output#1
Model16 JF-T-B-00 TEC-9100-4561000 1A Triac for SSR output#1, 2 A relay output #2

Legacy Series – Series 18 (2 outputs, 2 alarms)/TEC-8100 (2 outputs, 1 alarm)

If 2 outputs+ 2 alarms are needed use TEC-8300
8100’s available with retransmission/communication outputs RS485. RS232, 4-20mA, 1-5Vdc, and 0-10 Vdc
All 8100’s available in Low Voltage(11-26Vac/Vdc)
All 8100’s available with NEMA 4/X ratings
Universal input for TC’s (type J, K, E, B, R, S, N, and L)

Athena Catalog Number Tempco Part # Tempco Ordering Code Description
Model25-JF-B-0-0-0-0-00-1 TEC56002 TEC-4100-4510000 2A relay output #1
Model25-JF-B-B-0-0-0-00-1 TEC56001 TEC-4100-4511000 2A relay outputs # 1 & #2
Model25-JF-B-B-B-0-0-00-1 TEC56011 TEC-4100-4511100 2A relays outputs #1 & #2, 2A alarm relay
Model25-JF-F-0-0-0-0-00-1 TEC56003 TEC-4100-4530000 4-20mA output #1
Model25-JF-F-B-0-0-0-00-1 TEC56045 TEC-4100-4531000 4-20mA output #1, 2A relay output #2
Model25-JF-F-B-B-0-0-00-1 TEC56023 TEC-4100-4531100 4-20mA output# 1, 2A relay output #2, 2A alarm relay
Model25-JF-S-0-0-0-0-00-1 TEC56004 TEC-4100-4520000 5VDC pulse output #1
Model25-JF-S-B-0-0-0-00-1 TEC56032 TEC-4100-4521000 5VDC pulse output #1, 2A relay output #2
Model25-JF-S-B-B-0-0-00-1 TEC56014 TEC-4100-4521100 5VDC pulse output #1, 2A relay output #2, 2A alarm relay
Model25-JF-T-0-0-0-0-00-1 TEC56012 TEC-4100-4560000 1A Triac for SSR output #1
Model25-JF-T-B-0-0-0-00-1 TEC-4100-4561000 1A Triac for SSR output #1, 2 A relay output #2
Model25-JF-T-B-B-0-0-00-1 TEC-4100-4561100 1A Triac for SSR output #1, 2 A relay output #2, 2A alarm relay